External Influences on Feeding Accuracy and How These Can Affect Overall Ingredient Costs
Loss-in-weight feeder configuration
Loss-in-weight (LIW) feeder performance is affected by a number of influences, both internal and external to the feeder and feeder process. Understanding the significance of these influences is critical for achieving optimal performance. This article will describe some strategies to help ensure accurate weighing with your LIW feeder.
A LIW feeder is a gravimetric device that directly measures a material’s weight to achieve and maintain a predetermined feed rate that’s measured in units of weight per time (such as pounds or kilograms per hour). The LIW feeder, as shown in Figure 1, generally consists of a hopper, a refill device, a weight sensing device (digital or analog), a feeder (for example a screw feeder powered by a variable-speed motor), and a controller.
Before use, an operator programs the controller to discharge material at a predetermined feed rate (or setpoint). The feeder can either be mounted on a platform scale, as shown in Figure 2, or suspended on load cells, as shown in Figure 3. If the measurement taken by the weighing device is inaccurate or influenced by outside forces, the resulting mass flow from the feeder may be at risk. This inaccuracy results not only in an incorrect amount of material sent to the process below, it can also result in increased material costs due to the deviation from mass flow setpoint.
LIW feeders are used in both batch dispensing and continuous feeding applications. As manufacturers look to automate their processes with LIW feeding, they are also looking to optimize overall ingredient costs. Slight changes in the mass flow accuracy of a feeder or multiple feeders can make a significant difference in both product quality and in raw ingredient costs. A LIW feeder can be especially sensitive to ambient influences because it must precisely and continually measure very small differences in the weight of a relatively large load – the feeding equipment itself.
Ambient influences crucial to the weighing operation, such as environmental factors or improper installation and maintenance, include vibrations that are transmitted to the weighing system from nearby machinery, insufficiently flexible inlet/outlet connections, random physical shocks (such as bumping the feeder while in operation) and other mechanical disturbances as well as pressure variations within the system and at the process connections. Even air drafts and currents in the processing zone, if excessive, could affect weighing performance. Three of the main influences and solutions how to counteract them are described in detail below.
Figure 2: Coperion K-Tron Feeder mounted on a platform scale I Figure 3: Coperion K-Tron Feeder suspended on three load cells
Counteracting Ambient Vibrations
Vibration from other pieces of machinery can cause incorrect readings by the weighing device. To help compensate for any potential vibrations, Coperion K-Tron’s weighing technology and controllers use sophisticated filtering algorithms to be able to discriminate between the load to be measured and the transient forces imposed by vibration. When applied to the process data the algorithm helps the controller identify and extract frequency components characteristic of in-plant vibration, as shown in Figure 4. Even with such filtering algorithms, it is essential to further ensure that the feeder has a stable mounting by using the recommended shock mounts and platform acceleration measurements as recommended by your feeder supplier. In addition, when dealing with very low feed rate applications, it’s also important to eliminate strong air currents near the feeder, as the currents can move across the scale and influence the weight readings.
Figure 4: Weight sensor output shown with and without digital filter
Figure 5: Potential issues with bellows include overpressure causing the bellows to balloon (left) and under pressure causing the bellows to be sucked inwards (right).
Isolating the Feeder from Your System
Since the LIW feeder’s operation depends upon accurate weight measurements of the material in the hopper, it is imperative that the feeder and weighing devices are completely isolated from the upstream and downstream processes so as not to influence the overall weight signal. In the case of a continuous process, the upstream process may include a pneumatic receiver or a large hopper/IBC — both with a modulating valve. If this receiver or hopper is directly coupled to the feeder, the scale interprets the overall weight as much higher. Therefore, it’s essential that the feeder be isolated with flexible connections to both upstream and downstream equipment, with adequate space for maintenance.
One of the most common connection types is the flexible bellows. These bellows are typically constructed of a flexible elastomer, such as silicone. If these connections are too tight, too many tensile forces are exerted on the feeder below. This can cause the feeder controller to give an incorrect weight signal. Conversely, if the bellows are being sucked inward due to influences of pressure, these forces will also cause deviations in the weight signal. Figure 5 illustrates bellows designs that are too loose and too tight.
It is essential that the process connection isolates the feeder from any noise or force that may impact the feeder and scale performance. Often these issues may result after shutdown or maintenance has occurred, and the flexible connections have been re-installed improperly. If your feeder is experiencing performance issues after a maintenance program, the first place to troubleshoot is by examining the system’s flexible connections.
Compensating for Pressure and Vacuum Shifts
If a LIW feeder discharges material to a non-ambient-pressure environment, such as a pressurized conveying line, a pressure pulse (air leaking from the downstream system through the feeder’s discharge tube to the weight sensing device) can cause a feed rate error. Such a pressure pulse exerts a vertical force on the weight sensing device opposite to the hopper’s downward force. In effect, this force slightly lifts the load so the controller reads a lower weight than it should and decreases output to compensate for what it interprets as overfeeding. In addition, discharge pressure problems may be caused by extruder back pressure or vacuum, which are caused by changes in the downstream process. This could be back pressure in a mixer or extruder, or vacuum influences by a micronization or milling system, for example. To mitigate pressure fluctuations on the outlet, the cap may be isolated from the feeder by a flexible bellows rigidly mounted to an outside structure, such as a supporting frame.
At the same time, a feeder’s refill cycle increases air pressure in the hopper due to the sudden inflow of material. Any positive air pressure acts equally towards all sides and so also pushes up on the hopper lid and the refill valve. Because the force in the inlet area isn’t applied to the hopper lid but to the refill valve above, pressure forces inside the hopper aren’t balanced. Due to the inlet opening, forces acting upon the lid are lower than those acting oppositely on the floor of the hopper. These higher forces result in an increase in the weight signal. The LIW controller would interpret the increased weight signal to mean that mass flow is slowing and react by erroneously increasing the feeder output and creating a mass flow error.
Figure 6: Feeder with traditional mechanical pressure compensation on both hopper inlet and discharge
One of the most common sources of pressure fluctuations in LIW feeders is the presence of a clogged or blocked dust collection vent filter. Sometimes fluctuations can occur when the dust collection system or nitrogen blanket is connected across many feeders – when any of the feeders refill, the others experience pressure pulses transferred via the connected air lines.
Traditionally, these troublesome pressure fluctuations have been compensated for by mechanical means, as shown in Figure 6. However, factors such as mechanical tolerances, the alignment and age of the flexible bellows, and more can impact the mechanical pressure compensation and prevent the pressure from fully compensating for the forces generated by changing pressures, often making this costly solution deficient.
Figure 7: Electronic pressure compensation principle applied in a gravimetric feeding system.
Today there is an effective but simple alternative to mechanical pressure compensation: Coperion K-Tron’s Electronic Pressure Compensation (EPC). This solution has shown to significantly improve feeding accuracy of gravimetric feeders in closed systems and can be less expensive than traditional solutions. In addition, the electronic solution is more effective and reliable, maintenance free, and easy to retrofit on existing systems.
As shown in Figure 7, EPC is based on a high-precision pressure sensor which is mounted on the hopper lid and/or the outlet tube and constantly measures the pressure. The signal from the sensor is transmitted via sensor board to the feeder control system where it is used to dynamically compensate for the pressure fluctuations and thus prevent weighing errors. The pressure sensor can be installed on the feeder hopper or the outlet or both. It is also possible to use electronic pressure compensation for the hopper while utilizing traditional mechanical pressure compensation on the discharge.
In summary, it is important to remember that environmental influences such as vibrations, process connections and pressure fluctuations can have a direct effect on the accuracy of a LIW feeder. By implementing some of the optimization strategies outlined above, higher performance standards for continuous LIW feeding can be achieved as well as an overall increase in process profitability and quality.
Material Dynamics Carolinas, Inc (MDC) is the exclusive representative for Coperion K-Tron in North Carolina and South Carolina. Please feel free to contact us for more information.
Single Screw Feeders
Twin Screw Feeders
Quick Change Feeder QC
Bulk Solids Pump Feeders
Vibratory Feeders
Micro Screw Feeders
Pharmaceutical Design Feeders
Liquid Feeders
Smart Weigh Belt Feeders
Loss-in-Weight Belt Feeders
Smart Flow Meter
Continuous Gravimetric Blender
Gravimetric Batch Blender
Related posts
Equitech Int’l Corporation is a huge name in the data management and processing industry.